Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 64(2)2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37471587

RESUMO

OBJECTIVES: The Carpentier Perimount (CP) Magna Ease, the Crown Phospholipid Reduction Treatment (PRT) and the Trifecta bovine pericardial valves have been widely used worldwide. The primary end point of this study was to compare the haemodynamic performance quantified by in vivo echocardiograms of these 3 aortic prostheses. METHODS: The "BEST-VALVE" (comparison of 3 contemporary cardiac bioprostheses: mid-term valve haemodynamic performance) was a single-centre randomized clinical trial to compare the haemodynamic and clinical outcomes of the aforementioned bioprostheses. The 5-year results are assessed in this manuscript. RESULTS: A total of 154 patients were included. The CP Magna Ease (n = 48, 31.2%), Crown PRT (n = 51, 32.1%) and Trifecta (n = 55, 35.7%) valves were compared. Significant differences were observed among the 3 bioprostheses 5 years after the procedure. The following haemodynamic differences were found between the CP Magna Ease and the Crown PRT bioprostheses [mean aortic gradient: 12.3 mmHg (interquartile range {IQR} 7.8-17.5) for the CP Magna Ease vs 15 mmHg (IQR 10.8-31.9) for the Crown PRT, P < 0.001] and between the CP Magna Ease and the Trifecta prostheses [mean aortic gradient: 12.3 mmHg (IQR 7.8-17.5) for the CP Magna Ease vs 14.7 mmHg (IQR 8.2-55) for the Trifecta, P < 0.001], with a better haemodynamic performance of the CP Magna Ease. The cumulative incidence of severe structural valve degeneration was 9.5% in the Trifecta group at 6 years of follow-up. The 1-, 3- and 5-year survival from all-cause mortality was 91.5%, 83.5% and 74.8%, respectively (log rank P = 0.440). Survival from the composite event at the 1-, 3- and 5-year follow-up was 92.8%, 74.6% and 59%, respectively (log rank P = 0.299). CONCLUSIONS: We detected significant differences between the 3 bioprostheses; the CP Magna Ease had the best haemodynamic performance at the 5-year follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Animais , Bovinos , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemodinâmica , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
2.
Surg Infect (Larchmt) ; 23(10): 873-879, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36346276

RESUMO

Background: Post-sternotomy mediastinitis (PSM) is one of the most feared complications of cardiac surgery. The impact of a multidisciplinary management approach on this pathology is yet unknown. Patients and Methods: A multidisciplinary approach based on a co-management model (CMM) of care was initiated in January 2018 because of the incorporation of a hospitalist unit on a cardiac surgery department. An observational retrospective cohort study was designed to evaluate the impact of the CMM of care compared to the standard model (SM) of care in patients diagnosed with PSM. Our primary and secondary outcomes were survival time and treatment failure rate (two or more surgical procedures needed to solve PSM or PSM-related death), respectively. Data related to patient death date were collected from the Spanish National Death Index. A multivariable Cox regression model was created using those variables believed to be clinically relevant. Results: Ninety-one patients developed PSM from January 2010 to June 2020. Regarding the pre-operative clinical status, surgical procedure, and PSM severity, both groups had similar baseline characteristics. Patients were followed for a mean of 27.54 ± 30.5 months. A total of 60.3% of the SM group and 11.1% of the CMM group (p < 0.001) died. Treatment failure occurred in 53 patients (72.6%) in the SM group versus 7 (38.6%) in the CMM group (p = 0.007). The CMM independently reduced overall mortality (hazard ratio [HR], 0.11; 95% confidence interval [CI]. 0.01-0.83) and treatment failure rate (HR, 0.01; 95% CI, 0.001-0.183). Gram-positive bacterial infection (HR, 3.73; 95% CI, .6-8.3), and complete osteosynthesis material removal (HR, 0.47; 95% CI, 0.24-0.91) also influenced mortality in our model. Conclusions: A co-management care model reduced overall mortality in patients diagnosed with post-sternotomy mediastinitis.


Assuntos
Infecção Hospitalar , Mediastinite , Procedimentos Cirúrgicos Torácicos , Humanos , Estudos Retrospectivos , Esternotomia/efeitos adversos , Mediastinite/cirurgia , Procedimentos Cirúrgicos Torácicos/efeitos adversos
4.
J Clin Med ; 10(22)2021 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34830622

RESUMO

BACKGROUND: We aimed to compare 1 year the hemodynamic in-vivo performance of three biological aortic prostheses (Carpentier Perimount Magna EaseTM, Crown PRTTM, and TrifectaTM). METHODS: The sample used in this study comes from the "BEST-VALVE" clinical trial, which is a phase IV single-blinded randomized clinical trial with the three above-mentioned prostheses. RESULTS: 154 patients were included. Carpentier Perimount Magna EaseTM (n = 48, 31.2%), Crown PRTTM (n = 51, 32.1%) and TrifectaTM (n = 55, 35.7%). One year after the surgery, the mean aortic gradient and the peak aortic velocity was 17.5 (IQR 11.3-26) and 227.1 (IQR 202.0-268.8) for Carpentier Perimount Magna EaseTM, 21.4 (IQR 14.5-26.7) and 237.8 (IQR 195.9-261.9) for Crown PRTTM, and 13 (IQR 9.6-17.8) and 209.7 (IQR 176.5-241.4) for TrifectaTM, respectively. Pairwise comparisons demonstrated improved mean gradients and maximum velocity of TrifectaTM as compared to Crown PRTTM. Among patients with nominal prosthesis sizes ≤ 21, the mean and peak aortic gradient was higher for Crown PRTTM compared with TrifectaTM, and in patients with an aortic annulus measured with metric Hegar dilators less than or equal to 22 mm. CONCLUSIONS: One year after surgery, the three prostheses presented a different hemodynamic performance, being TrifectaTM superior to Crown PRTTM.

5.
Rev Esp Cardiol (Engl Ed) ; 74(8): 700-707, 2021 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32800747

RESUMO

INTRODUCTION AND OBJECTIVES: To help to illustrate the trends in isolated surgical aortic valve replacement (SAVR) in Spain, we performed a national-level analysis to investigate the changes from 1998 to 2017 in a) SAVR volume, b) patients' risk profiles, c) in-hospital mortality, and d) types of aortic valve prostheses. METHODS: We included all episodes of patients undergoing isolated SAVR from January 1998 to December 2017 recorded in the Minimum Basic Data Set (Ministry of Health, Consumer Affairs, and Social Welfare, Spain). The study duration was divided into four 5-year periods. We analyzed the trends in SAVR volume, comorbidity prevalence, and in-hospital mortality. Through multivariate logistic regression, we identified factors associated with mortality and type of prosthesis. The risk-adjusted mortality rate was compared over the study period. RESULTS: In total, 73 668 patients underwent an isolated SAVR from 1998 to 2017. The annual volume of procedures increased from 16 363 between 1998 and 2002 to 22 685 between 2013 and 2017. The prevalence of all investigated comorbidities increased, except for history of previous myocardial infarction and unplanned admission. The Charlson comorbidity index worsened from 1998-2002 (2.3; SD, 1.4) to 2013-2017 (3.6; SD, 1.7) (P <.001). In-hospital mortality decreased from 7.2% to 3.3% (P <.001) while the risk-adjusted mortality index improved from 1.3 to 0.7. The proportion of bioprostheses increased from 20.7% (1998-2002) to 59.6% (2013-2017) (P <.001). CONCLUSIONS: We detected an increase in the annual SAVR volume in Spain, with more patients receiving bioprostheses. Despite an increased risk profile of the patients, in-hospital mortality substantially reduced.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Humanos , Fatores de Risco , Espanha/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA